1. Determine the location of installation

Fixed partition and activity glass doors must be unified pay-off positioning, partition and glass doors of the positioning line according to the requirements of design drawings, locate frame, guide rail, to accurately measure the ground elevation and the frame at the top level.Note: this procedure must be performed after the completion of other procedures in the interior.

2. Installation of glass partition wall

Install the glass partition wall, the width of the door top limit slot should be greater than the glass thickness 2-4mm, the groove is between 20-30mm, in order to inject glue.The installation method can be used to draw the edges of two metal decorative plates from the center line of the projectile and then press the edge to install the ceiling slots at the top of the frame.The wooden pad in the slot is adjusted deep.Increase or decrease the adjustment of the pad.

3. Installation of steel frame

When the door body is narrower and lower, the steel frame is directly hit on the wall of the soil building, and the expansion screw is tight.When the door body is wider and higher, it is divided into the electric welding Angle in the upper part of the door into the steel channel, or the door of the door, reburning the door.After the steel frame is ready to burn, it is necessary to paint the steel frame with paint to prevent the steel frame from rusting.Then determine the glass size.

4. Installation of the track

Automatic door special orbit should be fixed on the steel frame, the high and low of the track need to be determined through the glass dimension, parallel to the steel frame, the left and right error cannot exceed 2mm.The track is fixed on the steel frame with self-tapping screw, and the normal single track needs 8-12 self-tapping screws, which are determined according to the length of the track.The surface of the installation track should be flat and no burr, and ensure that the aluminum alloy track is installed horizontally and vertically.

5. Installation of motor

Automatic glass door drive control box and automatic detection device is installed on the steel beam, the fixed connection with steel beam piercing bolt fixed way and steel beam welding connection plate connected to the fixed way again.It should be noted that the drilling or welding joint plates on steel beams should be completed before the steel beam is installed.

Install the door frame

Press the centerline of the projectile to set the door frame square, and then use plywood to determine the shape and position of the frame column (note that the trim size should be reduced).Finally, outsource the metal trim, and place the trim on both sides of the glass.Joint position must be accurate and vertical.

7. Glass installation

Use a glass sucker to absorb the thick glass, then hold the suction cup and lift the thick glass plate by 2-3 people and move it to the place of installation.Methods: foundation should insert frame at the top of the upper limit of the glass groove, and then put the bottom of the glass on tap to align the center line, and the installation location of good on both sides of the door frame, make the thick glass of two side just metal decoration face seam sealed doors, both inside and outside it invisible facing juncture.

8. Fixed glass

On tap wooden nail article two flat square inside and outside the thick glass caught in the middle, but from the plate glass need to set aside about 4 mm gap, and coating adhesive on the flat square bar will be facing plate sticking in the wood and two flat square bar.

9. Glass glue sealing

The glass glue is injected into the gap between the two sides of the top root slot and the glass slot of the bottom and the thick glass and the doorpost.The injection sequence should start from the end of a slot to the end of the end, without stopping.Operation main point is: hold caulking gun pressing handle the strength should be uniform, at the same time, the speed of moving along the crack to uniform, namely as the glass glue out, moving at a constant speed injection gate, make glass glue in aperture place form a homogeneous linear.Finally, remove the excess glass glue with a plastic sheet and wipe with a clean cloth

10. Connect the glass

Fixed part of the plate glass, because the width size is too big, must be assembled by two or more, two pieces of alignment stitching must form joint, butt seam should be 2-3 mm distance (glass incision for seam must be inverted).After the glass is fixed, want to use glass glue to enter a seam, fill hind also want to use plastic sheet to clean glue, make a seam to form a clean uniform line, the glass surface should use clean cloth wipe the glue trace.

11. Automatic glass door debugging

Switch on the power supply, adjust the detection Angle and response sensitivity of the microwave sensor, so as to achieve the best working condition.